1. Product Parameters

 

Item NameThree Phase TranformerRated Capacity400KVA
Item TypeSG-400KVARated Frequency50HZ/60HZ
Primary Voltage690V, 660V, 480V, 440V, 420V, 415V, 380V, 220V etc.Secondary Voltage415V, 380V, 220V, 208V, 200V etc (Customization available)
Insulation Resistance≥2 MΩInsulation ClassF
Output Accuracy±2%Cooling WayAir Cooling
Waveform DistortionNilPower Factor98%
Protection ClassIP44Response TimeLess than one second
TypeDry typeEnclosureWaterproof
Ambient Temperature-15~50℃Ambient Relavant Humidity20%-90%
Ambient Altitude<2000mVentilationSound ventilation required
Temperature RiseLess than 80℃DimensionCustomized

 

These are the basic parameters of 400KVA three phase transformer. Customized requirements could be accepted. If you have any request with regard to the enclosure, input voltage, output voltage, or connecting way etc., just tell us. The product could be customized according to your needs.

 

2. Product Introduction

 

The product mentioned here is a three phase isolation transformer, with rated capacity of 400KVA. The input voltage is 380V and the output voltage is 220V. The enclosure of this transformer is waterproof, with protection class IP44. It could effectively protects the main body of the transformer from water.

 

Three phase isolation transformer is widely used in industrial area. It works as a voltage change machine, helping to change a specific voltage value to another. It works with high efficiency and fast reaction rate.

 

3. Features

 

① Large capacity

② Strong load bearing capability

③ Waterproof characteristic

④ Strong electricity conductivity

⑤ Anti-interference

⑥ Delicate design

⑦ Customization availability

etc.

 

4. Usage Instructions

 

① Disassemble the wooden case, open the enclousre, and then check the appearance of the enclosure and the main body of this product.
② If the exterior enclosure and the interior main body is up to standard, then read the users' manual carefully to know how to connect wires and how to use it.
③ Fix the transformer in a well-ventilated place.
④ Then exam the circuit and the voltage of power grid. Normally deviation of ±5% is allowed. If the deviation is over this extent, please consider adding a voltage regulator in front in order to ensure the normal performance of this transformer.
⑤ Connect wires according to the wiring indication.
⑥ Checking the wiring carefully before you turn on the power.

 

5. Services

 

① Sampling service

② Model recommendation service

③ Relevant product recommendation service

④ Circuit diagram drawing service

⑤ Product design service

⑥ After-sale service

etc.

Get the latest prices? We will respond as soon as possible (within 24 hours)
This is an error tips
This is an error tips
This is an error tips
This is an error tips
This is an error tips
For a better browsing experience, we recommend that you use Chrome, Firefox, Safari and Edge browsers.